Fluke 62 Max Infrared Thermometer Not for to -22 Animer and price revision Human + Temp $70 Fluke 62 Max Infrared Thermometer (Not for Human Temp), -22 to + Industrial Scientific Test, Measure Inspect Temperature Humidity Fluke 62 Max Infrared Thermometer Not for to -22 Animer and price revision Human + Temp Industrial Scientific , Test, Measure Inspect , Temperature Humidity,Fluke,Thermometer,dead.af,for,62,to,Temp),,+,(Not,Max,-22,/flaccidness411884.html,Infrared,$70,Human Industrial Scientific , Test, Measure Inspect , Temperature Humidity,Fluke,Thermometer,dead.af,for,62,to,Temp),,+,(Not,Max,-22,/flaccidness411884.html,Infrared,$70,Human $70 Fluke 62 Max Infrared Thermometer (Not for Human Temp), -22 to + Industrial Scientific Test, Measure Inspect Temperature Humidity

Fluke 62 Max Infrared Thermometer Not for to -22 depot Animer and price revision Human + Temp

Fluke 62 Max Infrared Thermometer (Not for Human Temp), -22 to +

$70

Fluke 62 Max Infrared Thermometer (Not for Human Temp), -22 to +

|||

Product description

Style:62 MAX

IP54 rated for water and dust resistance. Features. Withstands a 9.8 foot drop Test. Temperature range 62 Max 22 to 932 Max 22 to 1202. Adjustable emissivity. High and low alarms. Dimension 6.8 x 3.3 x 2.9 inches.


From the manufacturer

"tbody" "th" Fluke 62 Max+ Infrared Thermometer "th" Fluke 62 Max Infrared Thermometer "th" Fluke 59 Max+ Infrared Thermometer "th" Fluke 59 Max Infrared Thermometer
IR Thermometer IR Thermometer
Temperature range -30°C to 650°C (-22°F to 1202°F) -30°C to 500°C (-22°F to 932°F) -30°C to 500°C (-22°F to 932°F) -30°C to 350°C (-22°F to 662°F)
Accuracy ±1.0°C or ±1.0% of reading, whichever is greater -10°c to 0°C: ±2.0 -30°C to -10°C: ±3.0 ±1.5°C or ±1.5% of reading, whichever is greater -10°c to 0°C: ±2.0 -30°C to -10°C: ±3.0 ±1.5°C or ±1.5% of reading, whichever is greater -10°C to 0°C: ±2.0 -30°C to -10°C: ±3.0 ±2.0°C or ±2.0% of reading, whichever is greater -10°C to 0°C: ±2.0 -30°C to -10°C: ±3.0
Response time (95%) lt;500 ms (95% of reading) lt;500 ms (95% of reading) lt;500 ms (95% of reading) lt;500 ms (95% of reading)
Spectral response 8 to 14 microns 8 to 14 microns 8 mm to 14 mm 8 mm to 14 mm
Emissivity 0.10 to 1.00 0.10 to 1.00 0.10 to 1.00 0.10 to 1.00
Optical resolution 12:1 (calculated at 90% energy) 10:1 (calculated at 90% energy) 10:1 (calculated at 90% energy) 8:1 (calculated at 90% energy)
Display resolution 0.1°C (0.2°F) 0.1°C (0.2°F) 0.1°C (0.2°F) 0.1°C (0.2°F)
Power AA battery AA battery 1 AA IEC LR06 battery 1 AA IEC LR06 battery
Battery life 8 hours with laser and backlight on 10 hours with laser and backlight on 12 hours with laser and backlight on 12 hours with laser and backlight on
Drop test 3 meters 3 meters 3 meters 3 meters